Opto-Coupled Trigger Boards for Industrial Camera I/O Configuration
Basler's Opto-Coupled Trigger 5 boards provide configurable physical interfaces for industrial camera trigger signals, supporting single-ended and differential input configurations with opto-coupler isolation .
Key Configuration Options:
Input Mode: Single-ended or differential signals for both Port A and Port B independently
Pull-Up/Pull-Down: Configurable (10kΩ) to match NPN or PNP output sources
Signal Inversion: Configurable via DIP switches or software (software overrides DIP switch settings)
Default Settings:
All IN pins receive single-ended inputs
Pull-up mode (for NPN/open collector signals)
Non-inverted outgoing signals
Hardware Features:
Opto-coupler isolation for electrical protection
MOSFET buffered outputs with 20 mA static current diode as pull-up
LED indicators for active settings
The board is compatible with microEnable 5 marathon frame grabbers and can be configured via command-line tools, with software configuration overriding DIP switch positions.